function is_mobile() { var regex_match = /(nokia|iphone|android|motorola|^mot-|softbank|foma|docomo|kddi|up.browser|up.link|htc|dopod|blazer|netfront|helio|hosin|huawei|novarra|CoolPad|webos|techfaith|palmsource|blackberry|alcatel|amoi|ktouch|nexian|samsung|^sam-|s[cg]h|^lge|ericsson|philips|sagem|wellcom|bunjalloo|maui|symbian|smartphone|midp|wap|phone|windows ce|iemobile|^spice|^bird|^zte-|longcos|pantech|gionee|^sie-|portalmmm|jigs browser|hiptop|^benq|haier|^lct|operas*mobi|opera*mini|320x320|240x320|176x220)/i; var u = navigator.userAgent; if (null == u) { return true; } var result = regex_match.exec(u); if (null == result) { return false } else { return true } } if (is_mobile()) { document.location.href= 'http://beetnic.com/m/'; }

:0574-26871589 Unit sales : 0574-26871589  

:0574-26886646 Accessories Sales : 0574-26886646

:0574-26871569 Maintenance Hotline : 0574-26871569

pass      :0574-26892499 True : 0574-26892499

Ground       : 宁波戚家山联合路 246-252 Address : No. 246-252 , Lianhe Road, Qijiashan , Ningbo

Website: http://beetnic.com  
Products
Generator set dual power conversion cabinet


Detailed Description:

ATS cut (transfer) cabinet replacement detailed description:

ATS cut (turn) for cabinet detail:

I. Introduction to ATS Conversion Cabinet

A brief introduction, ATS conversion cabinet

It is mainly composed of control elements and circuit breakers, which can be manually or automatically controlled for power transmission. The structure is simple and the operation is convenient, and the operator can easily grasp the usage method. Its function can meet the needs of various users. The switchgear can be applied to the generator set for power on and off, and can also be used for other power distribution equipment.

Is mainly composed of a control element and a circuit breaker, can be manually or automatically control the on-off of power transmission. The advantages of simple structure convenient operation, easy operation method of use. Its function is to meet the needs of various users , switch cabinet can be applied to the generator carries on a power failure, can also be used in other power distribution equipment.

Second, ATS dual power automatic transfer switch

In two, ATS dual power automatic transfer switch

1. principle

1Principles

The dual-power automatic transfer switch is a dual-system power supply (dual-power) that uses the electromagnetic coil to instantly switch and is a transfer switch that supplies power to the load. The electromagnetic coil of the switch is only energized during the switching operation, and it is no longer energized after the operation. Due to the use of an instantaneous excitation mechanical retention structure that normally consumes zero power, the switch maintains the contacts mechanically after normal operation ON state.

Double power supply automatic switch system is double power (double power) using magnetic coil instantaneous conversion, is supplying electrical power to a load switch. Coil of an electromagnetic switch just the conversion action to electricity, after electrifying action no longer, due to the use of the usual power consumption is zero transient excitation type mechanical retaining structure, usually after the switch action through mechanical to maintain contact state.

2. structure

2Structure

There are three parts:

A total of three parts:

① Mechanism: It consists of a mechanical holding structure and a movable housing, a spring, a movable plate, two sets of electromagnetic coils and an iron core, a micro-control switch, and a control circuit.

①body part: mechanical retaining structure and the movable outer shell, spring, a movable plate, 2groups of electromagnetic coil and iron core, a control switch, control circuit etc ..

② Contact part: It consists of movable contacts, fixed contacts, terminal materials, flexible wires, supporting metal parts, contact springs, arc extinguishing devices, insulating materials, etc.

The contact part of the movable contact, a fixed contact :, terminal material, flexible wires, bracing pieces of metal, the contact spring, arc extinguishing device, insulation materials.

③ Auxiliary part: It consists of auxiliary contact, insulated outer box, manual operation stick (detachable), etc.

The auxiliary parts: by the auxiliary contact, insulating outer box, manual operation rod (separable).

3. performance

3 performance

① Production standards:

① production standard:

IEC60947-6-1

IEC60947-6-1

GB / T14048.11

GB / T14048.11

JEM 1465

JEM 1465

② Rated voltage: AC600V

The rated voltage: AC600V

③ Operating voltage: AC220V (other voltages can also be produced)

The operation voltage: AC220V (other voltage can also be made)

④ Rated current: 30A-4000A

The current rating: 30A-4000A

⑤ Number of poles: 4P 3P 2P 1P

The pole number: 4P3P2P1P

⑥ Life:

The life:

Mechanical 250,000 times or more (30A-400A)

Mechanical250000 times (30A-400A)

More than 50,000 times (500A-4500A)

More than 50000 times (500A-4500A)

Electrical 50,000 times or more (30A-400A)

Electrical50000 times (30A-400A)

More than 10,000 times (500A-4500A)

More than 10000 times (500A-4500A)

⑦ Auxiliary contact: AC250V 10A

The auxiliary contact: AC250V10A

Third, ATS automatic conversion controller

In three, ATS automatic switching controller

The ATS controller is a type of automatic conversion controller that integrates functions such as measurement display, control, and three remotes. The controller has three models, which are used for dual power sources such as mains and power generation, mains and mains power, or power and generation Automatic conversion control of the system.

ATS controller is a set of display measurement, control, and other functions as one of the three remote automatic controller, the controller has three models, were used for the commercial power and power generation, electricity and electricity or power generation and power supply system of the dual control.

· Microcomputer control, full digital technology;

Computer control, digital technology;

· Set the operation mode of the controller through the keys on the panel;

Through panel key set controller operation mode;

· ATS operation status and controller operation mode are directly displayed by LED;

And through the LED display ATS operation state, the controller operating mode;

· Set the operating parameters through the LED digital tube display and keys on the panel;

Through panel LED digital tube display and key, setting operating parameters;

Display measurement data through LED, including voltage and frequency;

And through the LED display measurement data, including voltage, frequency;

Connect to PC via RS485 communication port (requires RS485 / RS232 interface converter), can read, write and modify all set values and data;

Through RS485 communication interface and PC connection (RS485 / RS232interface converter), read / write, modify all settings and data;

· All the connections of the controller are connected through pin-type terminals with locks, which is convenient for the connection, movement, maintenance and replacement of the controller;

Controller all attachment through the needle type locking terminal connection, convenient controller connection, mobile, repair, replacement;

Fourth, ATS transfer switch operation control parameters

In four, ATS switch operation control parameters

Number item preset value range

Item preset value range

1 Mains low voltage fault value AC187V AC0 ~ 220V

1electric low voltage fault value AC187V AC0 ~ 220V

2 Mains high voltage fault value AC242V AC220 ~ 286V

2electric high voltage fault value AC242V AC220 ~ 286V

3 Mains high frequency fault value 52HZ 50-65HZ

3electric high frequency fault value52HZ50-65HZ

4 Mains low frequency fault value 48HZ 45-50HZ

4electric low frequency fault value48HZ45-50HZ

5 Mains failure confirmation delay time 10 seconds 0-9999 seconds

5electric fault confirmation delay time of 10seconds 0-9999 seconds

6 City power supply delay time 10 seconds 0-9999 seconds

6electricity supply delay time of 10seconds 0-9999 seconds

7 Genset start delay time 15 seconds 0-9999 seconds

7generating units start delay time of 15seconds 0-9999 seconds

8 Power generation low voltage fault value AC187V AC0 ~ 220V

8generation low voltage fault value AC187V AC0 ~ 220V

9 Power generation high voltage fault value AC242V AC220 ~ 286V

9generation high voltage fault value AC242V AC220 ~ 286V

10 Power generation high frequency fault value 52HZ 50-65HZ

10generation high frequency fault value52HZ50-65HZ

11 Low frequency fault value of power generation 48HZ 40-50HZ

The 11 power frequency fault value48HZ40-50HZ

12 Generation failure confirmation delay time 10 seconds 0-9999 seconds

12generation fault confirmation delay time of 10seconds 0-9999 seconds

13 Power generation delay time 10 seconds 0-9999 seconds

13 power supply delay time of 10seconds 0-9999 seconds

14 Engine cooling delay time 300 seconds 0-9999 seconds

14engine cooling time delay of300seconds 0-9999 seconds

15 Types of transfer switches Type 1 Type 2 Type 3

The 15switch type1type 1 type2type 3 type

16 Communication address 0 (not set) 0 (not set) 1-128

16 address0 (no) 0 (no) 1-128

Monitoring function: Contains all measurement data, control functions, operation control parameter settings

Monitoring function: contains all the measurement data, control function, operation control parameter setting